The ventilation unit Ventoxx RV-30 S has been designed specifically for buildings with thin outer walls (wall thickness less than 300 mm), the residents of which should no longer give up all advantages of ventilation systems with heat recovery Ventoxx.
The innovative duct for outer wall hides the part of the ventilation unit which protrudes from the wall.
At a customer’s request, the duct (as well as external covers of our other units) may be painted in any color according to the German color standard RAL.
1. Inside cap;
2. 3D filter G3 class;
3. Reversible fan;
4. Insulation material;
5. Ceramic heat accumulator;
6. Plastic cover consisting of stacking rings;
7. Outside cover.
Number of operation modes | 17 |
Number of speed levels in reverse | 5 |
Ventilation volume in reverse, m³/h | 8-33 |
Rate of heat recovery, % | 70-91 |
Ventilation volume in “maximum ventilation” operation mode, m³/h | up to 100 |
Noise level, dB(A) | 21-43 |
Power requirement, W | 1,6-2,75 |
Power requirement during maximum ventilation, W | 4,78 |
Voltage, V | 230 VAC or 12 VDC |
Speed of Rotation, min-1 | 825/2205 |
Type of heat exchanger | High Tech heat accumulator |
Diameter of the Mounting Hole, mm | not less than 235 |
Operation temperature, °C | -20 up to +50 |
Operating Voltage, VDC | 12 |
Size |
Minimum length of telescopic pipe - 300 mm Diameter - 226 mm Inner cover: diameter - 240 mm Outer cover: height - 290 mm Width - 280 mm |
Type of positioning | Horizontal placement on outer wall |
Maintenance | Filter does not need any replacement. Cartridge with heat accumulator and filter should be checked every three months to make sure that cleaning is necessary. |
Protection Class: Fan Control |
IP 33 IP 20 |
Filter | G3 |
Class of energy efficiency | A |